Function Keys
1) Battery
Compartment: 2) LCD (Liquid
Crystal Display): Direct temperature
display. 3) Set Switch: Pressing this switch will
display the temperature setting. 4) Up Switch: Pressing
this switch together with the set switch will increase the
temperature setting by 1'c intervals. 5) Power
Switch: Main On/Off Switch. 6) Power On Indicator: Lights
up when power is applied and power switch is in
"ON" position. 7) Down Switch: Pressing this switch together
with the set switch will decrease the temperature setting by 1'c
intervals, holding the two switches for one second or more
will automatically decrease temperature setting down to Max.cool
temperature (-18'c) 8) Max Cool Switch: Pressing this switch
together with the set switch will set the temp setting to the max cool
temperature (-18'c) 9) Energy Saving Indicator: Lights up
when SC-35 is in energy saving mode
Operating Instructions
1)Plug into the DC power source per
the specified rating.
2) Press power switch to "ON"
position and the power indicator lights Up. 3) Press the set
switch to examine temp' setting. 4) To set lower temperature:
Press "Down Switch" (7) Together with "set switch" (3).The displaying
setting temperature, after1 second, will start count down until the
required set temperature is reached then release both switches. (Max. set
cool temperature -18'c) To set upper temperature: Press "Up
Switch (4) Together with "set switch"(3). The display setting
temperature, after 1 second, will start count up until the required
set temperature is reached. Then release both switches.
(Max set up temperature 10'c). Warning: Do not expose the SC-35 to rain.
For best performance, do not expose the SC-35 to direct
sunlight or near any heat sources |